|
 |
 |
DDG Analyzer System
|
| Product Type |
Producing Area |
| DDG-3300K |
Japan |
 |
DDG-3300K (Pulse Dye Densito-Graph Analyzer)
based on the spectroscopic assay theory , DDG-3300K detect ,measure and analysis the blood concentration and clearance rate of indocyanine green (ICG) ,which have been injected into circulation system from peripheral vein. DDG-3300K have many advantages over traditional manual method. DDG-3300K have been used for qualitative measurement of liver reservation function or global liver function with the parameter of ICG Retention Rate after 15 min (shorted for ICG R15 ) and Plasma Disappearance Rate of ICG (shorted for ICG K ). The other important application of DDG-3300K is the replacement of the traditional invasive thermo-dilution for the cardiac output and haemodynamics with non-invasive dye dilution and spectroscopic method. DDG-3300K have been used in large hospitals in USA, Japan , Europe., China Taiwan and mainland. |
 |
| The parameters on DDG-3300K |
| ICG K (ICG Retention Rate After 15 Min) |
ICG R15 (Plasma Disappearance Rate Of ICG) |
| Effective Hepatic Blood Flow (EHBF) |
Cardiac Output (CO) |
| Stroke Volume (SV) |
Blood volume (BV) |
| Cardiac Index (CI) |
Saturation of pulse O2 (SpO2) |
| Delivery of O2 (DO2) |
Pulse Rate (PR) |
|
 |
Main Equipment: Data processing center for indocyanine green trend, integrity, simplicity of operation, direct dislpay, powerful data precessing ability, change the raw data into clinical index right after test. It can store up to 50 group of data. Monitor saturation oxygen and pulse rate simultaneously, it can be done bedside anytime.
Probe: Key part to minitor indocyanine green concentration, it can emit and receive three band of ray, it has nose probe, finger probe and multi-functional probe according to test positions respectively.
Exclusive Computer: It is a center of processing and organizing data with exclusive software. It can receive data, create a data package, print, search, and backup automatically. Bring great convenience to clinical diagnostics and related research.
No Catheter Needed: Inject i.v. the tracing drug ICG(indocyanine green) and then monitor.Cadiac output can still be monitored? after take out the catheter with heat dilution method.
Monitor Without Noise In order to monitor steadily with patient breath change, minor pulse change and any other difficulty, this analysis system install the latest, powerful digital filter for pulse test exclusively, and introduce the light probe. |
| The Remarkable And Striking Advantages Of DDG-3300K Analyzer |
◆Non-invasive measurement
◆Only a transcutaneous sensor on nose wing or finger and any superficialvenous access for injection is needed for the measurement.
◆Quick measurement
◆Bed-side results are obtained within 5-10 minutes.
◆Specific and sensitive parameters
◆ICG elimination is well established for quantification of liver function, cardiac output, haemodynamics and splan |
 |
Liver Surgery / Liver Transplantatio
◆Prognosis evaluation and therapy guidance pre-liver resection in surgeryDept.
◆Diagnosis and Monitoring of liver dysfunction after liver surgery
◆ Diagnosis and Monitoring of graft dysfunction after liver
◆Transplantation
◆Qualitative measurement of liver reservation function of the living clonor for liver transplation avoid-
ing the liver failare after donation.
◆ Hepatology / Gastroenterology
◆ Early Diagnosis of acute decompensation of chronic liver disease
◆ Monitoring and prognosis of liver failure in patients suffering from chronic liver
◆ disease
◆ Risk prognosis of liver failure after liver intervention operation (radiofrequency ablation etc.)
ICU/Anesthesiology
◆ Diagnosis and Monitoring of liver dysfunction or decreased splanchnic perfusion,
◆ Prognosis evaluation in all criticaly ill patients, especially those with Sepsis / SIRS,Shock,Acute liver
◆ failure, Multiorgan system failure,Multiple trauma,ARDS / lung injury,
◆ Guidance for Fluid therapy
◆ Renal replacement therapies (fluid withdrawal)
◆ Adjunctive and supportive therapies
◆ Activated Protein C (Sepsis therapy)
◆ Liver support therapies
Cardiology and Heart surgery
◆ noninvasive measurement for CO, BV, CI etc.
◆ monitoring of cardiovascular operation and comment of the splanchnic perfusion
◆ prognosis of liver failure post operation in cardiac sugery
◆ noninvasive monitoring and operation indication decision for some congenital heart diseases
◆ aorticopulmonary fistula or window, neonate persistent pulmonary hypertension etc.
|
|
| Fittings Probe |
DDG-3300K Screen Menu |
 |
 |
|